EQA-Darts Portal guide for participating laboratories
Before you start

This guide plays by itself

  • Press Pause to stop and read. Press Play to continue.
  • Press Next to move to the following slide, or Back to return.
  • The buttons are under this slide. Click any bar beside them to jump to a part.
Back

Go to the previous slide

Pause

Stop here and read, then press Play

Next

Go to the following slide

Welcome

The EQA-Darts Portal

Send your results, follow each sample, and read your reports in one place.

Aim with Darts. Excel in EQA.

Log in

Start from eqadarts.org

  • Open eqadarts.org and press Participant login.
  • It takes you to portal.eqadarts.org.
  • Type your User and press Continue, then enter your Password and press Log in.
eqadarts.orgthenParticipant login
portal.eqadarts.org
UserYourLab
Password••••••••
Log in
First time

Use your claim code to set your own password

  • The coordinator gives you your User and a one-time claim code.
  • The first time, type your User and press Continue. Then enter the claim code, choose a password (at least 6 characters) and type it again to confirm.
  • The claim code works once only. From then on, log in with your User and your password.
First time
UserYourLab
Claim code••••••
Password••••••••
Confirm password••••••••
Log in
Every time after
UserYourLab
Password••••••••
Log in
Find your way

Four tabs, and all your labs at the top

  • One login covers all your lab numbers.
  • Pick the lab you want at the top of the screen (10, 11, 12, 13 …) and switch at any time.
  • At the top right, Change password lets you choose a new one yourself (6 or more characters). You do not need the coordinator.
  • Log out ends your session on this device only. Log out of all devices ends it on every phone and computer: use it if you lost a phone or used a shared computer.
  • Forgot your password? Ask the coordinator to reset it. You then get a new claim code and choose a new password.
Lab 10111213
Results Entry

Type and save your results for the open sample.

Dashboard

Your participation, warnings and rejections.

Reports & Certificates

Monthly reports, End of Cycle report, certificate.

Forms & Requests

Messages, complaints and changes to your details.

Results Entry

Type your results and save

  • Type the result for each test. If you work in another unit, choose it from the list beside the result.
  • Open Details ▾ under a test to choose its method and reagent source. The portal remembers them for the next sample.
  • The 📝 button on a test opens a private note for yourself. Only you can see it, on this device. It is never sent with your results.
  • Press Save results before the closing day.
Lab 10111213
Sample 2611
Test
Method, source
Unit
Result
Glucose
Details ▾
mg/dL
98
Creatinine
Details ▾
mg/dL
1.1
Sodium
Details ▾
mmol/L
140
📝 Private noteCreatinine: re-run if still high next month.
Save resultsSaved
Units

Work in the unit your lab uses

  • Choose your unit from the list beside each test.
  • To compare all labs fairly, the portal converts your result to the program's common unit.
  • Your report is then calculated back, so you read it in the unit you chose.
Glucose · Unit
mg/dLmmol/L
Result5.4
You enter5.4 mmol/L
Compared as97 mg/dL
Report shows5.4 mmol/L
Urea / BUN · TIBC / UIBC

Report what you actually measure

  • On the urea row, the unit list also offers BUN. Your BUN is compared with urea labs of the same method, and you still see your own unit.
  • On the TIBC row, choose I report: TIBC or I report: UIBC.
  • A UIBC lab types the UIBC. The portal takes the iron from your own Iron result (or you type it) and adds them to give your TIBC. Without iron, UIBC is not judged.
Urea · Unit
mg/dLmmol/LBUN mg/dLBUN mmol/L
TIBC row
I report: TIBCI report: UIBC
UIBC240+ Iron90=TIBC 330 µg/dL
Your test list

Reorder, rename and hide tests

  • Order: drag the handle or use the arrows.
  • My nickname: give a test the name your lab uses.
  • Hide: untick a test you do not run this month, and add a reminder of why.
  • Press Save. Reset to default brings the original list back.
Drag the handle or use the arrows to reorder, untick to hide, then Save. CancelReset to defaultSave
AnalyteMy nickname (optional)Include this monthReminder (e.g. why hidden)
↑ ↓AlbuminOptionalShownOptional reminder
↑ ↓ALPOptionalShownOptional reminder
↑ ↓ALTGPTShownOptional reminder
↑ ↓AmylaseOptionalShownNot run here
↑ ↓ASTGOTShownOptional reminder
Instrument name

Give each instrument a short name

  • Type a short name (up to 24 characters) in the Instrument name (optional) box, between Model and Lab #.
  • It is optional and saves when you click away: there is no Save button. You can change it at any time without asking the coordinator.
  • Instrument and model themselves are changed by request. See Modify my details later in this guide.
Lab 10111213
InstrumentAnalyser A
ModelA-400
Instrument nameEmergency lab
Lab #10
saved ✓
Mind the window

Submit before the closing day

  • Every sample has an opening day and a closing day, the same for all labs.
  • Results sent in time are judged in your report.
  • After the closing day, results are accepted only during a grace period set by the coordinator.
  • These late results are not judged and do not count as a participation.
Window opensClosing day
End of grace period
In timeFull report

SDI, % deviation and judgment for every test.

LateStatistics only

One page with the group figures. No SDI and no judgment.

Dashboard

Your year, lab by lab and month by month

  • Each cell: the number of tests you submitted, then the results with a warning (yellow) and the results rejected (red).
  • A count in red bold type means that submission was late.
  • Participate 8 times in the year to earn your Certificate of Participation. A late submission is not counted.
Participation overview – 2026 You've participated 10 times this year. You've reached the 8 needed for a Certificate of Participation. A late submission is not counted.
n warning (2 to 3 SDI from the comparator mean)n rejected (3 SDI or more)

This picture shows July to December. Your screen shows January to December of the current year.

Dashboard · TEa

Choose the TEa used to judge the % deviation of your results

  • At the bottom of the Dashboard, open “TEa used in your reports”.
  • For each lab number, pick the allowable total error (TEa) list you want. It saves at once, with no Save button, and applies to reports made from then on.
  • If you never choose, the default is used: BV desirable (biological variation, desirable, EFLM 2025). The other lists are BV minimum, BV optimum, CLIA and GOST.
▾ TEa used in your reports
Lab 10 · TEa list
BV desirable (default)BV minimumBV optimumCLIAGOST
Saved ✓
In your report

Your % deviation is compared with the TEa of your list. The % deviation itself does not change.

Reports & Certificates

Every monthly report, kept under your lab

  • Within a week of the closing day, the PDF report appears here.
  • Your coordinator also emails the PDF to your lab, as an attachment, with a note pointing to this portal.
  • Older samples stay in the list, so you can open them again at any time.
Lab 10111213
Monthly PT reports — Lab 10
PDFOct 2026NewDownload PDF
PDFSep 2026Monthly reportDownload PDF
PDFAug 2026Late: statistics onlyDownload PDF
SummaryAll tests together
Each testOne page per test
HistoryYour SDI over the months
Reading the report

See where each result landed

  • Each result gets an SDI: its distance from the comparator mean.
  • Yellow is a warning: 2 to 3 SDI from the mean.
  • Red is rejected: 3 SDI or more.
±2 SDI±3 SDI
Accepted Warning Rejected
End of Cycle

One report for the whole year

  • After the last sample of the cycle, you get an End of Cycle (EOC) report.
  • It sums up your performance across all the samples you took part in.
  • You find it in the same Reports & Certificates tab, in its own card called End-of-cycle report, and it is also emailed to your lab with the PDF attached.
Lab 10111213
Monthly PT reports — Lab 10
PDFDec 2026Monthly reportDownload PDF
PDFNov 2026Monthly reportDownload PDF
End-of-cycle report — Lab 10
PDFEnd of Cycle 2026All samples of the cycleDownload PDF
Forms & Requests

Write to the coordinator from the portal

  • Two forms are ready: Message to the Coordinator, and Participants/Customers Complaint.
  • Fill it and send. The reply comes by email or phone.
  • Everything you sent is listed under My sent forms & messages.
  • No login yet? Use the form at eqadarts.org/contact.
SubjectQuestion about sample 2611
MessageOur sample arrived late. Can we still send our results?
SendMessage sent
Modify my details

Ask for a change, the coordinator approves it

  • Edit your lab name, address or CC emails, add a phone, or ask to replace an instrument.
  • Primary phone and primary email cannot be changed here.
  • Submitting does not change your record right away. It takes effect once the coordinator reviews and approves it.
Request a change to your details
Lab nameExample Laboratory
CC email 1quality@example.org
Primary email (cannot be changed here)lab@example.org
Lab 10 — Analyser A, A-400Request to replace this instrument
Submit request
Submittedby your lab
Reviewedby the coordinator
Approvedchange takes effect
Survey

Tell us how we are doing

  • During the cycle, the portal opens a short satisfaction survey.
  • Give each question the rating that matches your experience.
  • Use the notes box at the end to add any details or evidence that can help us improve.
Participant satisfaction survey
Notes
Submit
Your portal
portal.eqadarts.org

Aim with Darts. Excel in EQA.

1Log in, and set your password the first time
2Pick your lab number at the top
3Set your units, test list and nicknames once
4Enter and save results before the closing day
5Follow your Dashboard and open your reports
6Use Forms & Requests to reach the coordinator